Products

Find the artificial intelligence based software for radiology that you are looking for.
All products listed are available for the European market (CE marked).

214/214 results

Logo
Subspeciality: MSK
Modality: MR

Radiation-free bone visualisation from MRI data

BoneMRI is a radiation-free software solution that generates a 3D CT-like (synthetic CT) image to visualize bone structures derived from an MRI scan. It is ideal to assist the diagnosis, monitoring ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro
Modality: CT

Volume of core and perfusion lesion, mismatch ratio, perfusion maps, AIF/VOF graph

icobrain cva allows the automated quantitative assessment of tissue perfusion by: - reporting the volume of core and perfusion lesion by quantifying Tmax abnormality and CBF abnormality together with ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro
Modality: MR

White matter abnormality quantification, brain volume change, report generation

icobrain ms helps physicians assess (sub)clinical disease activity in patients with multiple sclerosis. icobrain ms allows for the objective assessment of lesion dissemination in space and time ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro
Modality: MR

Volume quantification, asymmetry index, report generation

icobrain ep helps physicians with the detection of hippocampal sclerosis in patients with intractable (uncontrollable) epilepsy. The icobrain ep software aids the assessment of hippocampal asymmetry ...

CE:
Class I - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro
Modality: CT, MR

Volume quantification, brain volume changes, report generation, cisternal compression, midline ...

icobrain tbi aims to standardize the assessment of brain trauma. icobrain tbi for CT assesses mass effect by: - Quantifying compression of basal cisterns - Volumetric assessment of mass lesions - ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro
Modality: MR, CT

Brain region quantification, report generation, brain volume changes

icobrain dm aims to assists healthcare professionals in achieving a diagnosis of dementia and Alzheimer’s disease (AD). icobrain dm uncovers abnormality patterns by: - Reporting sensitive brain ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest
Modality: X-ray

Abnormality detection and localization, report generation, tuberculosis screening, worklist ...

qXR detects abnormal chest X-rays, then identifies and localizes upto 29 common abnormalities. It also screens for tuberculosis. **In the US, FDA 510(k) clearance only for facilitating confirmation ...

CE:
Class IIb - MDR
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest
Modality: CT

Pulmonary embolism detection, notification

The CINA-iPE solution provides automated detection and prioritization of incidental Pulmonary Embolism on CTA scans.

CE:
Class IIb - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
No
Logo
Subspeciality: Neuro
Modality: CT, MR

Automated post-processing, leakage correction, automatic coregistration, automatic motion ...

Cercare Perfusion aims to solve two problems - slow perfusion imaging post-processing and difficult-to-read perfusion maps. Cercare Perfusion aims to improve radiology workflow efficiency and ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac, Vascular
Modality: CT

Automatic measurement of aortic diameter, longitudinal comparison using prior exams

ARVA, “Augmented Radiology for Vascular Aneurysm“, is a solution for automatic measurement of the maximum transverse diameter of the aorta. ARVA provides the aortic maximum diameter, external wall ...

CE:
Class IIa - MDR
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest
Modality: CT

Fibrotic condition identification, percentage of lung affected, volume quantification, report ...

Lung Texture Analysis ™ from Imbio automatically applies computer vision to transform a standard chest CT into a map of the lung textures to identify ILD’s and other fibrotic conditions (normal, ...

CE:
Class IIa - MDD
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest
Modality: CT

Lung density quantification, abnormal lung region mapping, report generation

Lung Density Analysis™ applies big data analysis to paired inspiratory / expiratory chest CT studies to provide visualization and quantification of lung regions with abnormal tissue density. ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes