Logo
Subspeciality: Chest, Abdomen
Modality: CT

Incidental pulmonary embolism triage, prioritisation, notification

Aidoc's incidental pulmonary embolism algorithm is a triage algorithm that alerts clinicians to the presence of one or more suspected pulmonary embolisms in the central, lobar, segmental and sub-segmental vessels. This algorithm is run on contrast en

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest, Abdomen
Modality: CT

Aortic dissection triage, prioritisation, notification

Aidoc's aortic dissection algorithm is a triage algorithm that alerts clinicians to the suspected presence of an aortic dissection. This algorithm is run on contrast enhanced CTs as well as CT Angio exams.

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest, Abdomen
Modality: CT

Vertebral compression fracture, triage, prioritisation, notification

Aidoc's vertebral compression fracture algorithm is a triage algorithm that alerts clinicians to the suspected presence of vertebral compression fractures. This algorithm is run on chest and/or abdomen CTs with or without contrast.

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro, Cardiac, MSK, Chest, Abdomen, Breast
Modality: MR

MRI scan acceleration, MRI image enhancement

SwiftMR aims to accelerate MRI scans by up to 50% by enhancing low-quality initial outputs from accelerated scans. The deep-learning model improves SNR and resolution of MRI inputs, irrespective of ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro, Cardiac, MSK, Chest, Abdomen, Vascular
Modality: CT

Noise reduction of low dose CT

PixelShine is an algorithm for de-noising CT datasets supporting new CT protocols to drive patient dose down, while image quality is maintained. PixelShine may aid detectability of subtle pathologies ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Head/Neck
Modality: Ultrasound

Automated nodule recognition, quantification and visualization of sonographic features, risk ...

AmCAD-UT® Detection gives physicians a tool to process ultrasound images for sonographic characteristics that assist in making diagnostic decisions. AmCAD-UT® Detection uses statistical pattern ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest, Abdomen
Modality: CT

Aortic dissection triage, aortic dissection detection

CINA-AD is a radiological computer aided triage and notification software indicated for use in the analysis of chest and thoraco-abdominal CT angiographies. The device is intended to assist hospital ...

CE:
Class IIb - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro, Cardiac, MSK, Chest, Abdomen
Modality: CT

CT Image denoising for any body part

ClariCT.AI is an AI-powered CT image denoising solution to provide increased image clarity in CT examinations with excessive image noise due to either low dose or large patient. It is trained to work ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: MSK, Chest
Modality: X-ray

Bone suppression, super zoom, anatomical W/L, anatomical ABC, anatomical exposure index

TIRESYA is the core of Digitec's products featuring artificial intelligence algorithms. TIRESYA’s properties and functions are applied across the following radiology products: - ERACLE - Digital ...

CE:
Class IIb - MDD
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Multiple
Modality: MR

Automated generation of perfusion parameter maps and Vascular Input Function, anatomical image ...

IB DCE calculates parameters for solid tumor perfusion and permeability analysis. IB DCE includes the Tofts, Extended Tofts, and Patlak models. IB DCE can be used to monitor tumor response to ...

CE:
Class I - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Multiple
Modality: MR

ADC calculations, parameter normalization

IB Diffusion calculates ADC maps, and other diffusion parameters such as IVIM, Extrapolated b-value, and stretched exponential (Alpha and DDC) to probe abnormalities of tissue structure.

CE:
Class I - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac, Chest
Modality: CT

Ventricle diameter quantification, RV/LV ratio

RV/LV ratio can inform a physician on the severity of a Pulmonary Embolism by comparing the diameters of the right and left ventricles of the heart.

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
No